1. Introduction to Galileo
9
English
1.2 Operating modes
The functions of the Galileo computer
can be grouped into three categories,
each corresponding to a specifi c mode of
operation:
- surface mode: the computer is on the
surface. In this mode you can change
settings, review your logbook, use the
dive planner, see remaining desaturation
after a dive, download to PC and much
more;
- dive mode: the computer is at a
depth of 0.8m/3ft or more. In this
mode, Galileo monitors depth,
time, temperature and performs all
decompression calculations;
- sleep mode: the computer is on
the surface after 3 minutes without
operation. Though the computer
appears to be turned off completely, it
is still active. Galileo checks the ambient
pressure once every 60 seconds
for uninterrupted monitoring of the
environment.
1.3 Turning on Galileo and
time of day display
To start the computer, press and hold the
right button. The screen will briefl y show the
Galileo logo and then switch to the time of
day display. If you press the right button,
you will skip the start-up picture and go
straight to the time of day display. Think
of this as the home page of your new dive
computer. This is where it all starts.
The type of information displayed in surface
mode is different depending on whether
Galileo has remaining saturation from a
recent dive or is completely desaturated.
In case of no remaining saturation, the
display looks as depicted below. The
buttons are marked, from left to right, with
MENU, LOG and LIGHT. The top of the
display shows as default the Galileo logo,
which can be replaced by the fi rst two
lines of the owner information data (refer
to section 2.9.6 on owner information).
The time of day is shown in the middle of
the display. Underneath it, Galileo displays
various information: on the top row the
heart rate (see section 2.9.5), the current
temperature, the altitude class (in form of a
stylized mountain, see section 3.6) and the
battery capacity; on the lower row, the tank
pressure, the set oxygen concentration, the
corresponding MOD and the active MB level
setting (see section 2.3.1).
If the computer has remaining desaturation
from a recent dive, the upper portion of
the screen is replaced with the following
information: desaturation time, no-fl y time,
surface interval and CNS O
2
(if applicable).
The remaining desaturation time (DESAT)
is calculated by the decompression model
in the computer. Any dive started while
there is remaining desaturation on your
computer is considered a repetitive dive,
meaning that Galileo accounts for the pre-
existing nitrogen load in your body.
The no-fl y time (NO FLY) is the time during
which an exposure to the reduced pressure