3 Preparation for the dive
III UWATEC Aladin TEC 2G
or
until
3.1 Setting the gas mixture and ppO
2
max
Before every dive and after changing the tank, make sure that the settings
for the gas mixture correspond with the current mixture used. An incorrect
setting causes Aladin to miscalculate this particular dive. If the fraction of
oxygen is set too low this can lead to oxygen poisoning without warning. If
the value is set too high decompression sickness may occur. Inaccuracies in
the calculations are carried over to repetitive dives.
For dives with two gas mixtures please read page 37 for further reference.
To set the gas mixture, Aladin must be in user mode (
time of day display).
1. Push
or until the GAS 1 O
2
menu appears.
2.
Confirm that you wish to change the oxygen fraction of gas 1 by pushing .
3. Change the oxygen fraction in increments of 1% by pushing or
. Aladin will display the current fraction of oxygen, the maximum partial
pressure limit (ppO
2
max) and the MOD.
4. Confirm the selected percentage with .
5. By pushing
or you can change the ppO
2
max for the chosen frac-
tion of oxygen down to 1.0bar. Aladin will now display the corresponding MOD
for the new ppO
2
max.
6. Confirm your ppO
2
max settings with .
Without confirmation the display will disappear after 3 minutes and your
entries will not be accepted.
Automatic reset of the O
2
% mix to 21% can be set with "set 1" ->46 or Smart-
TRAK between 1 and 48 hours or to "no reset" (default).
Max Operating
Depth MOD
Change the ppO
2
max by
(+) and (–)
You have to check the settings of Aladin especially before the first dive. All set-
tings can be checked and changed directly at Aladin or via SmartTRAK.
WARNING
Change the O
2
% mix by
(+) and (–)
ppO
2
max